Soundwings for Prolyte ARC ROOF 6X4

Description

  • Soundwing set for arched roofs
  • Easy to use, quick setup
  • Significant loading capacity
  • Versatile application


STRUCTURE

  • Mainnet: H30D
  • Towers: H30V
  • Roof construction: arched roof
  • Stiffening: Guywires + pressure strips

LOADING CAPACITY:
Maingrid:

  • UDL - 1800 kg
  • CPL - 950kg
  • Point load combination - 2000 kg

PA Wing:

  • CPL per boom - 1000 kg

LOGISTICS

  • Self-weight construction: 600kg
  • Transport volume structure: 16m³
  • The exact numbers depend on the configuration and charging plan

ASSEMBLY:

  • Setup approximately: 4 hours (4 people)
  • Dismantling approximately: 4 hours (4 people)
  • All of these numbers depend on weather conditions, the number of people available and the skills of the crew.

DESIGN STANDARDS

  • ISO-17842-1 (2015): Safety of amusement rides and amusement devices - Part 1: Design and manufacture
  • EN 13814-1 (2015): Machinery and equipment for exhibition centers and amusement parks - Safety
  • EUROCODE 0 (EN-1990): Basics of structural planning
  • EUROCODE 1 (EN-1991): Measures on buildings
  • EUROCODE 3 (EN-1993): Design of steel structures
  • EUROCODE 9 (EN-1999): Design of aluminum structures
  • All components/structures are manufactured in accordance with EN1090 EXC3.
  • All structures are supplied with a structural report and manual - on-site training is mandatory

WIND MANAGEMENT

  • According to ISO-17842-1 (2015)
  • (Wind load applies to area Vb, 0 = 28m / s - terrain category III)
  • No service ; 0.44kN/m²; 26.5 m/s - 95.4 km/h (max. gust wind speed)
  • On duty ; 0.20kN/m²; 17.9 m/s - 64.4 km/h (max. gust wind speed)
  • Dimensions ; When reaching 17.9 m / s, the side and rear wall roofs are removed

ROOFING

  • Top, side and back
  • Standard side and back panels 100% closed - scrims available upon request.
  • Colour: gray on the outside, black on the inside - other colors on request
  • Roofing complies with fire-retardant standards B1 (ISO 9239-1)

BALLAST

  • Total: Varies between 1600kg - 6000kg
  • Per tower: Varies between 400 - 1550 kg

The amount of ballast depends on:

  • Dead weight of the structure (position of the tower)
  • Connected tower bases or freestanding towers
  • The use of an integrated staging system
  • Coefficient of friction between spindles, padding and subfloor

Staging

  • Layher scaffolding platform or Easyframe B-stage, optionally available.
  • Floor dimensions: variable
  • Floor height: max +/- 1.4 m
  • Floor load: 500kg / m² - 750kg / m²

SOUNDWING

  • Optionally available

GROUNDING

  • Optionally available

SIDE / BACKSTAGE AREA

  • None

LFTING

  • not included

BOM: